d Daisuke
on

 

DD0025 was not detected when I set MedDRA version as "19". I used PINNALCE21 Community 2.2.0, Define (PMDA) config. 

Is this an error ? Or, Is there any trigger data for DD0025.

      <CodeList OID="AEDIC" Name="AEDIC" DataType="text">
        <ExternalCodeList Dictionary="MedDRA" Version="19" />
      </CodeList>

 

Forums: Define.xml

s Sergiy
on April 19, 2017

Hi Daisuke, 

Yes, this check does not work in v2.2.0.

A bug was fixed a while ago. Please wait for a new v2.2.1 release soon.

Sorry for inconvinience.

Sergiy

d Daisuke
on April 20, 2017

Hi Sergiy,

Thank you for the information.

I 'll wait for V2.2.1 release.

I appreciate if declaration of compatibility on PINNACLE21 web site will be updated after V2.2.1 is released and compatibility to Enterprise Version V3.0.5 that PMDA uses is confirmed.

Daisuke