h Heidi
on

 

Hi,

after getting Warnings in Pinnacle 21 Community validator for SE variables in wrong order I had a look into config/SDTM 3.2.xml and found that for some of the SE variables the order defined there is not consistent with corresponding SDTM IG:

According to the SDTM IG 3.2 the order is:       ...-ETCD-ELEMENT-SESTDTC-SEENDTC-TAETORD-EPOCH-SEUPDES-SESTDY-SEENDY

According to config/SDTM3.2.xml the order is: ...-ETCD-ELEMENT-SEUPDES-TAETORD-EPOCH-SESTDTC-SEENDTC-SESTDY-SEENDY

Thus, the warnings we get seem not to be in line with SDTM IG 3.2

Do you agree?

Thanks, Heidi

Forums: SDTM

j Jozef
on January 26, 2017

Hi Heidi,

Is your problem related to the following forum entry: https://www.pinnacle21.com/forum/sd1079-wrong-order-added-variables-se ?