Hi Verna,
Thanks for the feedback. I corrected the inconsistencies and emailed you the updated configs. These will also be included in v2.1.1.
Best regards,
Max
At least AESEV is in error in 3.2 as well
Hi Max,
Would it be possible to send me the updated config files as well. I have a few issues related to incorrect labels in 3.2.
Thanks
Pierre
Just as a side comment, here is the link to a short article I wrote about this kind of issues:
http://cdiscguru.blogspot.com/2015/12/sdtm-labels-freedom-or-slavery.html
Hi,
I just use the latest community 2.1 to validate SDTM datasets (3.1.2). However, I found four wield hits which doesn't seem correct. The report output four label mismatch for AESEV and LBSTNRC, but I double checked and compare with the previous report. I think it might be a false alarm. Please share your thoughts.
AESEV, Severity/Intensity
LBSTNRC, Reference Range for Char Rslt-Std Units
TAETORD, Order of Element within Arm
IETESTCD, Incl/Excl Criterion Short Name