j Joan
on

 

Hi,

The IG for 3.1.3 and 3.1.2 has EXENDTC as permissible.  And that makes good sense for a per-instance recording scenario of an oral dose.

However, the validator is flagging an omitted EXENDTC column with the message, "SDTM Expected variable not found".

I recommend the configuration file be revised to treat EXENDTC as permissible.  Thanks!

Regards,

Joan

Forums: SDTM

s Sergiy
on April 1, 2015

Hi Joan, 

Thank you for reporting this issue!

We fixed it by correcting EXENDTC Core to "Permissible" in 3.1.2 and 3.1.3 specifications.

Kind Regards, 

Sergiy

m Michael
on August 5, 2015

Hi Joan.  Serigy is right, but also consider this point once you start to move towards 3.2, which is already almost a 2 year old standard for which the FDA plans to add to the data catalog very soon.

http://www.opencdisc.org/forum/ct2022-exendtc-expected-however-its-permissible#comment-1797