Hi Jeanna,
There is CT for QSCAT terms. Most likely you used QSCAT="BARS" in your data. In this case 'Barnes Akathisia Rating Scale Test Name' (C101809) CDISC controlled terminology codelist will be applied to QSTEST values.
Kind Regards,
Sergiy
Hello Sergiy,
I apologize but I do not understand your response. Yes I am using 'BARS' as the QSCAT and according to using that QSCAT I should be using the above QSTEST and QSTESTCD values, however they are producing errors. Are you saying that the QSCAT is incorrect and if so what is the QSCAT?
Kind Regards,
Jeanna
Hi Jeanns,
Actually this issue is similar to recently reported by Deepali. See http://www.opencdisc.org/forum/bug-config-sdtm-32xml
There are inconsistencies in CodeList codes across CDISC Terminology versions. Recently CDISC switched codes for 'BARS' Test Name and Test Code codelists. OpenCDISC works with original CDISC codes, while you are using a recent version of Terminology.
You should contact CDISC team and ask them to fix this error.
Thank you,
Sergiy
Hello,
I am getting CT0169 and CT0170 error in OpenCDISC QSTESTCD and QSTEST are not using CT however values look identical. My values are as follows:
QSTESTCD = 'BARS0101' QSTEST = 'BARS01-Objective'
QSTESTCD = 'BARS0102' QSTEST = 'BARS01-Subjective, Awareness'
QSTESTCD = 'BARS0103' QSTEST = 'BARS01-Subjective, Distress'
QSTESTCD = 'BARS0104' QSTEST = 'BARS01-Global Clinical Assessment'
Please advise. Is there possibly an issue occurring in OpenCDISC or do I not have something set up correctly? All other CT for QS is not reporting any issue. I greatly appreciate your response.