Hi Catherine,
My assumption is that in TS domain you have another record with TSVAL='NONE', and a missing value for TSVALCD.
Kind Regards,
Sergiy
Hi Sergiy,
Yes, I have another two TSPARMCD = "STOPRULE", "STRATFCT" with TSVAL = "NONE".
Should I add TSVALCD for these two as the same as TCNTRL did?
Thank you.
Yes, you should use TSVALCD consistently across all records in the domain.
Hi,
Could you please perform this check only for TSVCDREF = CDISC ?
We got this error because for a study : TSVAL = 3.2 when TSPARMCD = DOSE, and TSVAL = 3.2 when TSPARMCD = SDTIGVER.
Thanks and Regards,
Hi Sophie,
Thank you for reporting this issue! We definitely need to improve algorithm for SD1278 rule.
Kind Regards,
Sergiy
Hi,
I'm get a warning message SD1278 from Pinnacle 21 report: "Inconsistent value for TSVALCD within TSVAL when TSPARMCD = TCNTRL, TSVAL = NONE and TSVALCD = C41132."
I only have a record for the TSPARMCD = TCNTRL.
I checked CT for TSVAL = NONE that was document with Code = C41132 and Codelist Name = Control Type Response.
Not sure why I got this message and how to resolve it.
(SDTMIG : 3.2, SDTM CT: 2020-06-26, Pinnacle 21 version: 3.0.2)
Attached Files