v Venkata
on

 

We have a genuine below issues for one of our project.

 

RFSTDTC Derivation: look for first treatment date from EX domain – if its missing then we read randomization date and time from IVRS dataset – if bothe missing then RFTSDTC should be null.

RFENDTC Derivation: maximum end date of the subject in the study will come from subject visit (SV) dataset.

 Issue is:

1.       We have 4 subjects who were actually screen failures but site made IVRS call and its recorded and assigned randomization number, date and time.

a.       Above subjects RFSTDTC info came from IVRS dataset – but subject ARM is “Screen Failure”.

b.      Above subjects RFENDTC derived by picking maximum date from SV – but subject had single visit – which is earlier than RFSTDTC date and time – its firing “HIGH-SEVERITY” check when validating SDTM checks.

2.       We have subject who randomized and took study treatment and discontinued on same day.

a.       We were collecting date and time of the dose – RFSTDTC contains valid date and time from EX dataset.

b.      SV dataset does not contain time – RFENDTC has identical date but time is missing (which we don’t collect) - its firing “HIGH-SEVERITY” check when validating SDTM checks because time value is null for RFENDTC element.

Does it okay, if acknowledge this issue at SDTM level and document it in data review doc before submitting these data to FDA? Or do we have any other better options to handle above situations – I greatly appreciate your swift help – thanks in advance.

 

Forums: SDTM

s Sergiy
on June 5, 2013

Hi Venkata,

 

Yes, you should explain to FDA all "not-fixable" data management issues in a special document- "Reviewers Guide".

 

Another option could be to re-evaluate your derivation algorithms for RFSTDTC and RFENDTC variables. However they are expected to be clear and consistent across all your studies within a submission.

I would recommend discussing with your team what is it the best option for your particular case?

Regards,

Sergiy Sirichenko

OpenCDISC

v Venkata
on June 6, 2013

Normal 0 false false false EN-US X-NONE X-NONE

In my perspective, capturing screen failure data always a tricky because we don’t have full control on real time concerns ( things may not happen the way it kept on guidelines and what we intended) in our case – I don’t see anything wrong in the database – site was mistakenly made a call to IVRS system and IVRS system did its job (as expected) and CRF clearly stated 4 were screen failure subjects. We cannot do anything more here unfortunately.

As I said we have below options to correct in SDTM domains:

Screen Failures: Change RFSTDTC and RFENDTC derivation for this project – RFSTDTC and RFENDTC should be null if subject is screen failure – don’t look for any dates in EX and IVRS datasets.

Not collected visit time: Add time value as “23:59:59” as a default value for all subjects who randomized – it will take care of the subjects who discontinued on same day of randomization.

Above steps will satisfy the Open CDISC validation checks but my concern is does it acceptable practice to do it?

I was thinking on below options as well –

1.Acknowledge the issues in SDTM domains and document it.

2.Correct the RFSTDTC and RFENDTC @ ADSL level ( we have more flexibility at ADaM level than SDTM level) – that will take care of analysis level issues if any.

Here I am looking for industry experts opinion - which is the best way to move forward – I greatly appreciate your swift suggestions and assistance.

 

Thanks,

Venkata Maguluri.

s Sergiy
on June 6, 2013

RFSTDTC and RFENDTC should be null if subject is screen failure – don’t look for any dates
in EX and IVRS datasets.

In general, this is not good approach, because you are losing information about Randomization, which very important for review. FDA statisticians have special procedures around analysis of Randomization data. You have to submit Randomization results and additional information for study protocol violations in DV domain.

For subjects who failed screening criteria, but were actually randomized by mistake, ARM variable values are “Treatment X”, “Placebo”, etc., but not “Screen Failure”.

ARM/ARMCD values are defined by Randomization process. Additional values like “Screen Failures” and “Not Assigned” can be used only for subjects who were not randomized.

 

SD1002 (RFSTDTC is after RFENDTC) check should handle a case when both time points are on the same day and at least one variable has only date part (missing time part). You do not need to populate time as “23:59:59”, which is a kind of imputations to avoid in SDTM data.

Regards, 

Sergiy

v Venkata
on June 7, 2013

Thanks lot for swift response - it helpfull info:).

 

Venakta Maguluri.